Make sure all instruments are reading correctly. Vacuum gage leaks will cause high absolute pressure readings.
It should be at design or slightly higher.
Exhaust steam temperature should be 240 °F or higher with suction blanked off.
Look for vacuum system leaks if a single-stage ejector pulls 27-28” Hg. in a closed test.
Check all exhaust piping to make sure it is large enough and unrestricted.
These occur mostly during the first weeks of operation. Unscrew nozzle inspection plug and check.