Charts & FormulasA handy reference set for your use
|
| Staging Chart Line Sizing |
Pressure Conversion |
1.0 Standard Atmosphere is equivalent to: |
| 14.696 psi |
| 33.9 ft of H2O |
| 29.921 in of Hg |
| 760 mm of Hg |
| 1.0332 kg/cm² |
| 101.325 kPa |
| 1.01325 Bars |
|
|
|
 |
|
|
| Pressure Conversion Line Sizing |
| Staging Chart |
| # of Stages | Operating Suction Pressure (Hg Abs.) | Closed Test Suction Pressure (Hg Abs.) |
| 1 | 3" and up | 1½ - 2" |
| 2 | 10 mm - 4" | 5 mm |
| 3 | 2 - 15 mm | 1 mm |
| 4 | 0.25 - 3 mm | 50 - 100 microns |
| 5 | 0.3 mm and less | 5 - 10 microns |
| |
|
|
| Staging Chart Pressure Conversion |
| Suction or Steam Line Sizing |
| d = ( 0.051 * W * v / V )½ |
d = pipe inside diameter, in inches
W = total flow, in pounds/hour
v = specific volume, in cubic feet/pound
V = velocity, in feet/second (typically 200 ft/sec) |
| |
|
DISCLAIMER: Artisan Industries Inc provides this page as a convenience to our visitors. However, we make no claim as to the accuracies of these charts and formulas and we are not responsible for any errors resulting from their use. |